The Cozmanager™ System


Price: $4800 | Back to Main Pump Page

The CoZmanager System is a Microsoft® Windows®- based program that allows the pump to communicate with a computer.

The CoZmanager™ System consists of 3 parts:
1. Personalize: this page is used for pump programming, including: Personalizing your Deltec Cozmo® Insulin Pump - you can program everything for the pump, including setting up basal patterns and rates and all of your bolus settings; you can also create custom text according to your needs, create custom names for basal patterns, create custom meal boluses (up to 12) and create custom names for these boluses, create custom temporary rates (up to 8), and create custom names for these rates, customize certain screens and information on the home screens, create a customized message that will display should the Automatic Off alarm occur. Saving pump programs - you can save all the program setting for your pump. This way you have a complete record of how your pump is personalized. Printing and/or e-mailing your pump program - you can quickly and easily print out or e-mail all of your personalized pump settings.

2. History: this page is where you can perform all history functions, including view pump history - you can download all of the history reports stored in your pump’s memory onto your PC. Download and save pump history - by saving a complete record of your pump’s history, you can review and spot trends in you diabetes management program. Printing and/or e-mailing your history reports - You can quickly and easily print out or e-mail history reports.

3. Configure: this page is used to configure The CoZmanager™ System. You decide whether you want access to The CoZmanager™ System to be password controlled (you must create a password), you want general instructions to be displayed during start-up of the program, you want The CoZmanager™ System to offer to print the pump’s program when you get it from or send it to the pump. Other features: “Help” is displayed right on the screen, and help for a specific task can be viewed by pressing the ? icon near the group box. Functions such as getting information from the pump, delivering information to the pump, saving, and e-mailing are performed by clicking buttons. In order for the pump to communicate with a computer, your computer must have an IR adapter.

Equipment and Software Requirements
•Windows® 98, ME, 2000, or XP Operating System
•CD-ROM drive
•Hard drive with at least 20 MB available
•Mouse or other pointing device
•Display settings set to True color or High color, with 800 x 600 or greater resolution
•Built-in IR port or external IR Adapter (iFoundry IrDA USB Adapter, model IFSYS-8003A from iFoundry Systems or equivalent)
•CoZmanager™ PC Communications System

Features of the Deltec Cozmo

CoZmonitor® blood glucose module attachment
The only “all-in-one” system with integrated pump and glucose monitor.Stores test results to the Deltec Cozmo® pump automatically

Enhanced Meal Maker®
Choose between a number of foods (and their carbohydrate amounts) and the pump calculates the total grams of carbohydrate in your meal and suggests the appropriate bolus according to your insulin-to-carbohydrate ratio. Matches your eating patterns and preferences because you can add your favorite foods and meals in the CozFoodsTM feature.

Missed Meal Bolus reminder
Set reminders in case you forget to take a meal bolus. Helps you avoid unintentional high blood glucose levels.

Bolus by grams of carbohydrate
Enter the amount of carbohydrate grams eaten and the Deltec Cozmo® pump calculates the correct insulin dosage in units of insulin. Lowers your chance of bolusing too much or too little.

Waterproof
Shower and swim confidently.

Bolus increments
Adjust bolus increments in as small as 0.05 units per hour. Determines insulin dosing more precisely.

Weekly Schedule
Set single or recurring basal patterns to automatically change by day of the week. Makes your Deltec Cozmo® insulin pump more like a PDA.

Disconnect
Detach from the pump from 15 minutes up to 2 hours. Helps you calculate missed basal insulin and suggests you bolus before and after you disconnect.

Basal Rate Testing
Evaluate basal rate patterns by taking fasting basal pattern tests morning, noon, and even overnight. Lets you see if fasting blood glucose is in control or if basal patterns should be changed for better control.

Blood glucose test reminder
Set reminders to test your BG after meals or at specified times during the day. Helps maintain blood glucose.

CoZmanager® 2.0 PC communications software
Personalize the Deltec Cozmo® insulin pump to your special needs and preferences. Enhances reporting capabilities

Correction bolus
Program the pump to calculate appropriate insulin dosing to correct a high blood glucose test result. Tracks “Active Insulin On Board” to help prevent you from stacking correction boluses, helping reduce the risk of hypoglycemia.

Program Lock-out
Prevent unauthorized pump reprogramming. Gives security and control to parents, healthcare providers, and other caretakers.

QuickStart
Set up basic functions on the Deltec Cozmo® insulin pump in one, easy place. Starts you on pump therapy quickly.

Site Change reminder
Set reminders when you need to change your infusion site. Helps reduce the risk for site irritation and infections with regular site changes.

Therapy Effectiveness Scorecard
Get detailed bolus histories and report averages. Makes it easier to monitor and modify your insulin therapy.

Full-size cartridge
The 300 unit plastic cartridge is lightweight, easy to fill and easy to load into the pump.  Also to view the remaining insulin in the cartridge there is an easy to read gauge on the display.

Infrared (IR) port
The IR port on the back of the Deltec Cozmo® insulin pump provides two functions:

  1. It  Allows the CoZmonitor®  Blood Glucose Module to communicate with the Deltec Cozmo® insulin pump.
  2. It also allows the CoZmanager® 2.0 PC communications software to communicate with the Deltec Cozmo® insulin pump to personalize and program your pump settings as well as download all pump history.

Touch bolus button
The exclusive touch bolus button on the side of the pump lets you easily deliver a meal bolus without looking at your pump's screen.

Small size
The Deltec Cozmo® insulin pump is small, about the size of a cell phone, and only weighs 3.3 ounces (w/ battery and full cartridge).  Its ergonomic design fits comfortably in the palm of your hand for convenient one-finger programming.

Easy to use keypad
Easy to use keypad relates to the menu on the display window, similar to navigating a menu on a cell phone.

Large display window
The large LCD display is easy to read, day or night, with its anti-glare lens and backlighting.  It can show full text and graphics, and the pull-down menu makes programming your pump a snap.

Easy to buy batteries
The Deltec Cozmo® insulin pump is powered by a single AAA battery.  Changing it is easy, and there's a battery life indicator right on the display home screen.

Size (in.) 3.5 x 2 x .75
Weight (oz.) 2.7 - Empty
3.3 - With battery & full reservoir
Reservoir Type 300 unit / disposable plastic
Reservoir Volume Indicator displays units of insulin remaining in cartridge on pump home screen
Basal Increments 0.05 units
Basal Rate Intervals 3 minutes
Temporary Basal Rates Custom rates programmed by units/hour or as a percent change from existing basal rate
Maximum Basal Rate 35 units/hour
Basal Patterns 4 customizable basal patterns can be created
Total Basal Rates Up to 48 rates in each pattern
Bolus Amounts 0.05 to 25 units
Bolus Increments Can be customized at 0.05, 0.1, 0.5, or 1 units
Bolus Duration All boluses will be delivered within one minute
Bolus Programming Method Units of insulin or by carbohydrate
Bolus Types Standard, Extended, and Combination
Bolus Programming Methods Visual and Touch bolus
Correction Bolus User specific data is used to calculate suggested correction bolus for high blood glucoses. Feature also is used to compensate for past boluses taken that are not fully used
Custom Meal Bolus Up to 12 specific meal bolus modes can be created
Memory 2000 events
Computer Download Two-way infrared communication with PC
PC Application My Treatment Assistant™ software allows user to download pump data and upload pump settings from PC
Home Screen Home screen can be customized with personal user text
Battery Type One AAA Battery
Status Indicator Indicates remaining battery life on home screen
Waterproof Yes -for swimming and other water activities
Warranty 4 years
Backlight Yes
Date and Time Display Yes - home screen and sleep mode
Alarm Can be set to either beep or vibrate
Automatic Off Pump Alarm can be programmed to alarm and stop delivery if no keys have been pressed in a specified amount of time
Program Lock Pump lockout with security code
Downstream Occlusion Alert Yes
Missed Meal Bolus Alert Alerts you if a meal bolus has not been taken
Blood Glucose Test Alert Alerts you to test your blood glucose at specific times
Infusion Set Change Reminder Alert Alerts you when you should change your infusion set

Please email us for more information.